OdorEyes EcoSystem B/U
Odorant Injection

TheEcoSystem B/U Pulse Gas Odorizer takes bypass odorizing to a new level. Using today’s technology, we can overcome the problems associated with the old conventional buried bypass odorizer. The most significant advance in bypass technology has been the introduction of the bypass odorizer. Rather than relying on a constantly changing differential pressure across a restriction in the pipeline, the pulse-bypass odorizer pulses a known volume of gas through the odorant tank proportional to flow. This makes it a true flow tracking odorizer. The unique control technology incorporated in the EcoSystem B/U can provide continual odrization even in theevent of loss of meter signal or power failure. The pulse bypass system can operate accurately down to zero flow and will never vapor lock. It is ideal for stations that may periodically cease operation or go to extremely low flow. When the flow returns or increases it will remain accurate and reliable. Additionally, the system can be equipped with a temperature sensor in the odorant tank. The bypass flow is adjusted to compensate for changes in odorant vapor concentration due to temperature changes. This OdorEyes feature allows the tank to be either buried or above ground and remain accurate.

 