The Welker MSTCC Mixing Skid is designed for use with Welker Crude Oil Containers. The Mixing Skid conforms to the requirements of API - 8.2 and ISO-3171. The MSTCC is a properly designed and sized mixing system to take full advantage of the design features of the Welker TCC series containers and provide a quality sample for BS&W analyzers.
Download more information. |
|
Welker AVA-1 & AVA-2 Volume Analyzer |
|
The “Bite Checker” Volume Analyzer is used for monitoring sampler volumes or for chemical pump volume verification. The Welker Volume Analyzer can be interfaced with control systems for sampler function verification, totaling, shutdown or other monitoring purposes.
Download more information. |
|
Eesiflo Watercut Monitors |
|
Available in 1" thru to 48" sizes, loop powered hazardous area approval.
Low range to 25%, high range version 0-100%.
Addresses the needs of oil production and distribution, Aviation, Chemical and Pharmacutical industris.
Download more information. |
|
Sampler Probes Model SP & PP |
|
Sampler Probes are available in a variety of threaded or flanged connection sizes, probe sizes and lengths.
For sampling the end of the tube should be set within the centre 1/3rd of the pipeline.
Tube ends can be straight 45° or 95°. Special purpose ends can be supplied as well.
If the end of the tube has a chamfer or 90°end, the upstream direction of the tube is indicated with an arrow engraved on the upstream side, at the end of the boss.
Specific insertion lengths can be supplied or users can cut the tube to suit the installation. The insertion length can be tagged or engraved on the unit as an option.
Download more information. |
|
Adjustable Sampler Probe Model AP3 & AP4 |
|
The adjustable sample probe is designed to be inserted and withdrawn manually into a pressurised pipeline. The depth of insertion can be set at any desired length.
A locking gland once set, locks the probe at a set insertion length. After this has been set the tube can then be retracted by removing the locknut and loosening off the locking gland. For sampling the end of the tube should be set within the centre 1/3rd of the pipeline.
The probe may be inserted with the pipeline under pressure providing the force required to insert the probe is not too great. If the force required is too great it will be impossible to insert the probe under pressure, or there is a danger that the probe could be damaged/bent.
The recommendation is that no more then 30kg force is used.
Download more information. |
|
EnPro PT-2 Pneumatic Timer |
|
The EnPro range of pneumatic timers have been developed to satisfy the need for small portable, accurate pneumatic timers, that will actuate samplers or valves in hazardous environments where protected electrical/electronic devices present problems with complexity and weight.
Download more information. |
|
|
<< Start < Prev 1 2 3 Next > End >>
|
|
Page 3 of 3 |